GSM Development

GSM Remote Development

GSM (Global System for Mobile Communications, originally Groupe Spécial Mobile), is a standard set developed by the European Telecommunications Standards Institute (ETSI) to describe protocols for second generation (2G) digital cellular networks used by mobile phones.

The GSM standard was developed as a replacement for first generation (1G) analog cellular networks, and originally described a digital, circuit switched network optimized for full duplex voice telephony. This was expanded over time to include data communications, first by circuit switched transport, then packet data transport via GPRS (General Packet Radio Services) and EDGE (Enhanced Data rates for GSM Evolution or EGPRS).

Further improvements were made when the 3GPP developed third generation (3G) UMTS standards followed by fourth generation (4G) LTE Advanced standards.

"GSM" is a trademark owned by the GSM Association.

Access

Remote GSM Gate Access

 

 Product Description:

Up to 50 Authenticated Users can have access, depending on model. One Manager to Add & Remove Users. Works with Vodacom SA Network at the moment. Activating the output is a missed call and charge free from a cell phone. Airtime can be loaded from any Vodacom Cell phone that has the facility and is only used for return sms. Easy to install and Users are added via simple SMS from Manager Cell phone Only.

Specifications:

12v Battery from Gate access motor supply or alarm panel. Needs to be in an Area of Vodacom Cell phone reception. Output can be pulse or toggle. High or low (Normally Open) Product carries a 1 Year Guarantee subject to terms and conditions.

Other Uses:

·         In toggle mode can be used to switch on any device via correct interface, including but not limited to:

      ·         Home alarm,

      ·         Geyser heating,

      ·         Outside Lights or Internal Lighting,

      ·         Access Control to Gates, Doors, Safes,

      ·         Secure Locations.

 

Alarm

Alarm to SMS

Product Description:

Can be used in 12 volt car or truck alarm system as well. Up to 5 Authenticated Users can be SMS'ed in the event of an alarm trigger. One Manager to Add & Remove Users. Works with Vodacom SA Network at the moment. Standard Rate SMS per Message. Airtime can be transferred from any Vodacom Cell phone that has the facility. Easy to install and Users are added via simple SMS from Manager Cell phone Only.

Specifications:

12v Battery from vehicle battery supply or alarm panel. Needs to be in an Area of Vodacom Cell phone reception. Can Monitor Battery Voltage as well. Can be used to activate and de-activate alarm system from remote Product carries a 1 Year Guarantee subject to terms and conditions.

Other Uses:

 

·         Digital input pulse trigger in pulse mode to relay message of pulse presence.

 

i.        Motion detection via Passive sensor or Ultra sonic sensor. e.g. Silent alarm

 

ii.      Entry report via infra red beam.eg. Perimeter security.

 

iii.    Break counter via infra red or ultrasonic sensor. e.g. Font door customer counter.

 

Digital input in State mode to relay current state or change of state.eg Power failure.
 

Vehicle

Vehicle Monitor via SMS

Product Description:

Monitors Engine Liquid Temperature( for some lady drivers), Battery Voltage and Lights. Can be used in 12 volt car or truck. Up to 5 Authenticated Users can be SMS'ed in the event of a fault. One Manager to Add & Remove Users. Works with Vodacom SA Network at the moment. Standard Rate SMS per Message. Airtime can be transferred from any Vodacom Cell phone that has the facility. Easy to install and Users are added via simple SMS from Manager Cell phone Only..

Specifications:


12v Battery from 12 volt vehicle Battery supply. Needs to be in an Area of Vodacom Cell phone reception. Output can be pulse or toggle. High or low (Normally Open) Product carries a 1 Year Guarantee subject to terms and conditions.

Other uses:

     ·         Analogue Mode:

 

i.        Read Battery Voltage. (12 volts battery voltage low)

 

ii.      Monitor Water Temp. (For overheating- Women Drivers)

 

iii.    Monitor water level in tank via float sensor

 

·         Digital Mode:

 

iv.    Monitor Lights on if ignition is off. ( Forgetting your lights on )

 

v.      Rev Counter to check engine Running. ( For HHO Generator )

 

vi.    Airbag trigger SMS.

 

vii.  Secret button for security, Flat tire or no water.

 

viii.Look4Me Vodacom location tracking or with added gps can send location co-ordinates.

 

ix.    Optional vehicle disable or reduce functionality from remote.

 

x.      Optional Speaker phone for communication with driver

 

Temperature

Temperature Monitor via SMS

 

Product Description:

Monitors Fridge or Freezer or Geyser Temperature(-50 to +150 Celsius). Up to 5 Authenticated Users can be SMS'ed in the event of a fault. One Manager to Add & Remove Users. Works with Vodacom SA Network at the moment. Standard Rate SMS per Message. Airtime can be transferred from any Vodacom Cell phone that has the facility. Easy to install and Users are added via simple SMS from Manager Cell phone Only..

Specifications:

  
12v Supply from 12 volt Adapter or Battery with Charging circuit. Needs to be in an Area of Vodacom Cell phone reception. SMS charged at Standard SMS Rates. Product carries a 1 Year Guarantee subject to terms and conditions.

Other Uses:

 

i.        Room Temperature sensor.

 

ii.      Water temp sensor.

 

iii.    Heat switching to 125 degrees Celsius

 

iv.    Cooling switching to -55 degrees Celsius

 

Intercom

Remote Intercom

 

Product Description:

Allows remote communication via button pressed, code entered or number dialled on keypad. Calls a list of numbers in phone book  (up to 200 numbers. Allows bi-directional communication & DTMF control.

Specifications:

 

a.       7-12volts dc Supply.

 

b.      Has to be in cell phone signal area.

 

Can be connected to a solar charger for remote locations.

Other Uses:

 

i.        In-call dtmf control access.

 

ii.      5 button call for elderly. MEDICAL, FIRE, MECHANICAL, SAFETY, URGENT

 

iii.    Multiple intercom to call directors or management staff without supplying there cell numbers.

 

Code requires call access then dtmf to operate access gate or door.